Learning objectives
- Understand the key concepts of this chapter
- Apply them safely in the operating theatre
Study notes
The OT table, shadowless lights, suction machine, electrosurgical unit, anesthesia machine, monitors and defibrillator are checked before the list starts. Suction pressure, light focus and table movements are tested, and a logbook records checks and faults. Equipment is switched off and cleaned after use. Preventive maintenance is done on schedule.
Medical gases come from pipelines or cylinders and are colour-coded as per the national standard. Cylinders are stored upright and secured, and oil or grease must never touch oxygen fittings because it can catch fire. Gas outlets, pressure gauges and alarms are checked, and a backup power supply such as a generator or UPS must be ready.
Important points
- Check equipment before every list
- Record faults in the logbook
- Keep oxygen fittings free of oil
- Secure cylinders upright
Key terms
Shadowless light Suction Medical gas pipeline Preventive maintenance
Practice MCQs on OT Equipment, Lights and Medical Gases
Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.
Questions 1 to 10
1. OT lights are called shadowless because they:
- Cast strong shadows
- Reduce shadows over the surgical field
- Have no bulbs
- Are always dim
Show answer
Even lighting helps surgeons.
2. Before the list starts the suction machine is checked for:
- The label
- Its color
- Adequate suction pressure
- Its weight
Show answer
Test it before use.
3. An OT logbook is used to record:
- Parking
- Staff lunch times
- Menus
- Equipment checks and faults
Show answer
Supports maintenance.
4. Preventive maintenance of OT equipment is done:
- Never
- Only when it breaks
- On a planned schedule
- Once in ten years
Show answer
Prevents breakdowns.
5. Oil or grease on oxygen fittings can cause:
- Fire
- Cooling
- Rust only
- Better flow
Show answer
Never lubricate oxygen fittings.
6. Gas cylinders should be stored:
- Upright and secured
- Near heat
- Lying loose on the floor
- In a wet corridor
Show answer
Prevents falls and leaks.
7. Medical gases are identified by:
- Colour coding as per the national standard
- The size of the cylinder valve only
- The order in which cylinders were delivered
- A label written by the staff on tape
Show answer
Check the label too.
8. A backup power supply in the OT is:
- A candle
- A battery for watches
- A generator or UPS
- A torch only
Show answer
Needed for life-support equipment.
9. A defibrillator in the OT should be:
- Stored in another building
- Unplugged
- Ready and tested
- Locked away
Show answer
For emergencies.
10. An OT table should be checked for:
- Smooth movement and locks
- The label
- Its color
- Its brand
Show answer
Safe positioning.
Questions 11 to 20
11. The electrosurgical unit is checked for:
- Intact cables and a working return pad lead
- The brand name written on the pad
- The age of the monitor beside the unit
- The color of the footswitch and the cable
Show answer
Prevents burns.
12. The pressure gauge on a gas cylinder shows:
- The cost
- The age
- The temperature
- How much gas is left
Show answer
Check before use.
13. If a piece of equipment is faulty you should:
- Repair it yourself
- Report it, tag it and remove it from use
- Ignore it
- Use it carefully
Show answer
Prevents harm.
14. After use equipment is:
- Covered dirty
- Switched off and cleaned
- Moved to the corridor
- Left running
Show answer
Basic care.
15. Earthing and electrical safety checks protect against:
- Rust
- Electric shock
- Noise
- Fogging
Show answer
Done by engineers.
16. A gas pipeline alarm sounding means:
- Open the window
- Check the gas supply immediately
- Ignore it
- Switch off the alarm and continue
Show answer
Pressure may be low.
17. Cables and tubing should be arranged so that they:
- Hang over the sterile field
- Cross the floor
- Are tied in knots
- Do not trip staff or get pulled
Show answer
Prevents accidents.
18. A pulse oximeter and ECG monitor are checked:
- For the brand
- For weight
- For color
- For working leads and alarms
Show answer
Alarms must be audible.
19. Equipment manuals and service records are:
- Kept at home
- Hidden
- Thrown away
- Kept available for staff
Show answer
Needed for safe use.
20. A defective OT equipment item should be:
- Hidden in a corner
- Cleaned only
- Used if urgent
- Tagged and removed from use until repaired
Show answer
Prevents patient harm.
Related chapters
- Chapter 15: Preoperative Preparation and Patient Transfer
- Chapter 16: Post-operative Care and Recovery Room
- Chapter 18: Biomedical Waste and Specimen Handling in OT
- Chapter 19: General Surgery Procedures
Continue learning
OT Technician interview questions Mock tests MCQ practice
Frequently asked questions
How many OT Equipment, Lights and Medical Gases MCQs are available?
This page has 20 free MCQs on OT Equipment, Lights and Medical Gases with answers and explanations. More are added over time.
Is OT Equipment, Lights and Medical Gases practice free?
Yes. You can practice without login or payment.
Are these official OT Technician exam questions?
No. They are original practice questions written for learning.