ETO Sterilization – CSSD MCQ Questions and Study Notes

Ethylene oxide (EtO) is a low-temperature gas sterilant used for many heat-sensitive devices. Practice free CSSD MCQ questions on this topic below.

Take the ETO Sterilization practice test All 45 chapters

Learning objectives

Study notes

EtO kills microorganisms by alkylation of cellular components. Effective cycles depend on gas concentration, temperature, humidity and exposure time.

EtO is toxic, flammable and carcinogenic. After the cycle items require aeration to remove residues. Staff exposure is monitored and the area must have proper ventilation.

Important points

Key terms

Alkylation Aeration Exposure limit Humidity

Practice MCQs on ETO Sterilization

Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.

Questions 1 to 10

1. EtO sterilizes by:

  1. Heat
  2. Radiation
  3. Alkylation
  4. Freezing
Show answer
Answer: C. Alkylation
Alkylates microbial DNA/proteins.

Report an error in this question

2. After an EtO cycle items need:

  1. Freezing
  2. Painting
  3. Immediate use
  4. Aeration
Show answer
Answer: D. Aeration
Removes residue.

Report an error in this question

3. EtO is:

  1. Toxic and flammable
  2. Edible
  3. Harmless
  4. Non-reactive
Show answer
Answer: A. Toxic and flammable
Handle carefully.

Report an error in this question

4. Key EtO cycle parameters include:

  1. Color and weight
  2. Concentration, temperature, humidity, time
  3. Label
  4. Noise
Show answer
Answer: B. Concentration, temperature, humidity, time
Core parameters.

Report an error in this question

5. Staff exposure to EtO should be:

  1. Monitored
  2. Ignored
  3. Increased
  4. Hidden
Show answer
Answer: A. Monitored
Safety compliance.

Report an error in this question

6. Residual EtO in patient items can:

  1. Help healing
  2. Cause tissue injury
  3. Improve sterility
  4. Be ignored
Show answer
Answer: B. Cause tissue injury
Hence aeration.

Report an error in this question

7. Adequate humidity helps EtO to:

  1. Penetrate and act
  2. Cool
  3. Rust
  4. Explode
Show answer
Answer: A. Penetrate and act
Moisture aids efficacy.

Report an error in this question

8. EtO is chosen for:

  1. Liquids
  2. Food
  3. Heat/moisture sensitive items
  4. All steel items
Show answer
Answer: C. Heat/moisture sensitive items
Low-temperature option.

Report an error in this question

9. EtO areas should have:

  1. Ventilation and alarms
  2. No training
  3. Open food
  4. No signage
Show answer
Answer: A. Ventilation and alarms
Safety controls.

Report an error in this question

10. Aeration time is set by:

  1. Staff choice
  2. Guess
  3. Manufacturer and validated cycle
  4. Item size only
Show answer
Answer: C. Manufacturer and validated cycle
Follow validated parameters.

Report an error in this question

Questions 11 to 20

11. ETO is generally used at temperatures of about:

  1. 160 °C
  2. 37–55 °C
  3. 0 °C
  4. 121 °C
Show answer
Answer: B. 37–55 °C
India practice: low-temperature sterilization.

Report an error in this question

12. Biological indicator for ETO sterilization is:

  1. Candida
  2. Geobacillus stearothermophilus
  3. Bacillus atrophaeus
  4. E. coli
Show answer
Answer: C. Bacillus atrophaeus
India practice: also called Bacillus subtilis var niger.

Report an error in this question

13. ETO is dangerous because it is:

  1. Heavy
  2. Cold
  3. Sweet
  4. Toxic and flammable
Show answer
Answer: D. Toxic and flammable
India practice: hazardous to staff, needs aeration.

Report an error in this question

14. After an ETO cycle, items should:

  1. Be soaked
  2. Be used immediately
  3. Be aerated before use
  4. Be frozen
Show answer
Answer: C. Be aerated before use
India practice: removes residual gas.

Report an error in this question

15. Humidity during ETO sterilization should be:

  1. Very dry only
  2. Adequate (roughly 40–80%)
  3. Not controlled
  4. Zero
Show answer
Answer: B. Adequate (roughly 40–80%)
India practice: moisture assists gas action.

Report an error in this question

16. Why is ETO used for certain devices?

  1. It is fastest and cheapest for every item
  2. It works at low temperature and penetrates packaging and lumens
  3. It leaves no residue and needs no aeration
  4. It works only on thick metal instruments
Show answer
Answer: B. It works at low temperature and penetrates packaging and lumens
Useful for heat-sensitive items.

Report an error in this question

17. A health risk linked to ETO exposure is:

  1. Irritation and a cancer risk with long exposure
  2. Better eyesight
  3. Lower blood pressure
  4. Nothing
Show answer
Answer: A. Irritation and a cancer risk with long exposure
Strict controls are needed.

Report an error in this question

18. ETO sterilizers should be placed in:

  1. A closed cupboard
  2. A well-ventilated area with monitoring and alarms
  3. The corridor
  4. The kitchen
Show answer
Answer: B. A well-ventilated area with monitoring and alarms
Protects staff.

Report an error in this question

19. A main drawback of ETO is:

  1. Long cycle plus aeration time
  2. It needs no packaging
  3. It is too cold
  4. It leaves no residue
Show answer
Answer: A. Long cycle plus aeration time
Time and safety limits.

Report an error in this question

20. ETO is often mixed with another gas to:

  1. Change its color
  2. Make it sweeter
  3. Reduce its flammability
  4. Make it heavier
Show answer
Answer: C. Reduce its flammability
Safer gas mixtures.

Report an error in this question

Related chapters

Continue learning

CSSD interview questions Mock tests MCQ practice CSSD NABH checklist

Frequently asked questions

How many ETO Sterilization MCQs are available?

This page has 20 free MCQs on ETO Sterilization with answers and explanations. More are added over time.

Is ETO Sterilization practice free?

Yes. You can practice without login or payment.

Are these official CSSD exam questions?

No. They are original practice questions written for learning.