ETO Sterilization – CSSD MCQ Questions and Study Notes
Ethylene oxide (EtO) is a low-temperature gas sterilant used for many heat-sensitive devices. Practice free CSSD MCQ questions on this topic below.
Take the ETO Sterilization practice test All 45 chapters
Learning objectives
- Understand the key concepts of this chapter
- Apply them in safe practice
Study notes
EtO kills microorganisms by alkylation of cellular components. Effective cycles depend on gas concentration, temperature, humidity and exposure time.
EtO is toxic, flammable and carcinogenic. After the cycle items require aeration to remove residues. Staff exposure is monitored and the area must have proper ventilation.
Important points
- Aeration is mandatory
- Monitor staff exposure
- Cycle depends on temperature, humidity, time, gas
- Follow safety limits
Key terms
Alkylation Aeration Exposure limit Humidity
Practice MCQs on ETO Sterilization
Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.
Questions 1 to 10
1. EtO sterilizes by:
- Heat
- Radiation
- Alkylation
- Freezing
Show answer
Alkylates microbial DNA/proteins.
2. After an EtO cycle items need:
- Freezing
- Painting
- Immediate use
- Aeration
Show answer
Removes residue.
3. EtO is:
- Toxic and flammable
- Edible
- Harmless
- Non-reactive
Show answer
Handle carefully.
4. Key EtO cycle parameters include:
- Color and weight
- Concentration, temperature, humidity, time
- Label
- Noise
Show answer
Core parameters.
5. Staff exposure to EtO should be:
- Monitored
- Ignored
- Increased
- Hidden
Show answer
Safety compliance.
6. Residual EtO in patient items can:
- Help healing
- Cause tissue injury
- Improve sterility
- Be ignored
Show answer
Hence aeration.
7. Adequate humidity helps EtO to:
- Penetrate and act
- Cool
- Rust
- Explode
Show answer
Moisture aids efficacy.
8. EtO is chosen for:
- Liquids
- Food
- Heat/moisture sensitive items
- All steel items
Show answer
Low-temperature option.
9. EtO areas should have:
- Ventilation and alarms
- No training
- Open food
- No signage
Show answer
Safety controls.
10. Aeration time is set by:
- Staff choice
- Guess
- Manufacturer and validated cycle
- Item size only
Show answer
Follow validated parameters.
Questions 11 to 20
11. ETO is generally used at temperatures of about:
- 160 °C
- 37–55 °C
- 0 °C
- 121 °C
Show answer
India practice: low-temperature sterilization.
12. Biological indicator for ETO sterilization is:
- Candida
- Geobacillus stearothermophilus
- Bacillus atrophaeus
- E. coli
Show answer
India practice: also called Bacillus subtilis var niger.
13. ETO is dangerous because it is:
- Heavy
- Cold
- Sweet
- Toxic and flammable
Show answer
India practice: hazardous to staff, needs aeration.
14. After an ETO cycle, items should:
- Be soaked
- Be used immediately
- Be aerated before use
- Be frozen
Show answer
India practice: removes residual gas.
15. Humidity during ETO sterilization should be:
- Very dry only
- Adequate (roughly 40–80%)
- Not controlled
- Zero
Show answer
India practice: moisture assists gas action.
16. Why is ETO used for certain devices?
- It is fastest and cheapest for every item
- It works at low temperature and penetrates packaging and lumens
- It leaves no residue and needs no aeration
- It works only on thick metal instruments
Show answer
Useful for heat-sensitive items.
17. A health risk linked to ETO exposure is:
- Irritation and a cancer risk with long exposure
- Better eyesight
- Lower blood pressure
- Nothing
Show answer
Strict controls are needed.
18. ETO sterilizers should be placed in:
- A closed cupboard
- A well-ventilated area with monitoring and alarms
- The corridor
- The kitchen
Show answer
Protects staff.
19. A main drawback of ETO is:
- Long cycle plus aeration time
- It needs no packaging
- It is too cold
- It leaves no residue
Show answer
Time and safety limits.
20. ETO is often mixed with another gas to:
- Change its color
- Make it sweeter
- Reduce its flammability
- Make it heavier
Show answer
Safer gas mixtures.
Related chapters
- Previous: Hydrogen Peroxide Plasma / VH2O2
- Next: Chemical Indicators
- Chapter 7: Low Temperature Sterilization
- Chapter 8: Hydrogen Peroxide Plasma / VH2O2
- Chapter 10: Chemical Indicators
- Chapter 11: Biological Indicators
Continue learning
CSSD interview questions Mock tests MCQ practice CSSD NABH checklist
Frequently asked questions
How many ETO Sterilization MCQs are available?
This page has 20 free MCQs on ETO Sterilization with answers and explanations. More are added over time.
Is ETO Sterilization practice free?
Yes. You can practice without login or payment.
Are these official CSSD exam questions?
No. They are original practice questions written for learning.