Instrument Cleaning & Decontamination Techniques – CSSD MCQ Questions and Study Notes

Manual and mechanical cleaning methods remove soil using detergent, water quality control, friction and mechanical action. Practice free CSSD MCQ questions on this topic below.

Take the Instrument Cleaning & Decontamination Techniques practice test All 45 chapters

Learning objectives

Study notes

Manual cleaning uses soft brushes, detergent and rinsing under the water surface to avoid aerosols. Lumened devices need appropriately sized brushes and flushing.

Ultrasonic cleaners use cavitation to loosen soil from crevices. Devices are opened, degassed water is used, and cleaning is followed by rinsing. Different metals should not be mixed unless the IFU allows.

Washer-disinfectors run pre-wash, wash, rinse, thermal disinfection and drying phases. Loads must be arranged so spray reaches all surfaces.

Always follow the manufacturer's IFU for detergents, temperature and brushing.

Important points

Key terms

Cavitation Washer-disinfector Lumen Degassing Neutral pH detergent

Practice MCQs on Instrument Cleaning & Decontamination Techniques

Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.

Questions 1 to 10

1. Manual brushing should be done:

  1. In the hallway
  2. Dry
  3. Above the water
  4. Below the water surface
Show answer
Answer: D. Below the water surface
Prevents aerosolization.

Report an error in this question

2. Ultrasonic cleaning works through:

  1. Cavitation
  2. Radiation
  3. Steam
  4. Heat
Show answer
Answer: A. Cavitation
Cavitation bubbles dislodge soil.

Report an error in this question

3. Why degas ultrasonic water?

  1. To save water
  2. To warm it
  3. To add color
  4. To remove air that reduces cavitation
Show answer
Answer: D. To remove air that reduces cavitation
Dissolved air weakens cavitation.

Report an error in this question

4. Which phase follows washing in a washer-disinfector?

  1. Packaging
  2. Rinse
  3. Recall
  4. Storage
Show answer
Answer: B. Rinse
Rinsing then thermal disinfection and drying.

Report an error in this question

5. Lumened instruments require:

  1. Any brush
  2. No cleaning
  3. Only wiping
  4. Correctly sized brushes and flushing
Show answer
Answer: D. Correctly sized brushes and flushing
Ensures full lumen cleaning.

Report an error in this question

6. Overloading a washer can:

  1. Improve cleaning
  2. Sterilize items
  3. Shorten cycles
  4. Block spray coverage
Show answer
Answer: D. Block spray coverage
Spray must reach every surface.

Report an error in this question

7. Cleaning parameters should be taken from:

  1. Manufacturer IFU
  2. Supplier ads only
  3. Coworker habit
  4. Guessing
Show answer
Answer: A. Manufacturer IFU
IFU is the authority.

Report an error in this question

8. Instruments with hinges should be:

  1. Opened during cleaning
  2. Tied
  3. Wrapped
  4. Closed
Show answer
Answer: A. Opened during cleaning
Opening exposes joint surfaces.

Report an error in this question

9. A neutral pH detergent is often preferred because it:

  1. Corrodes metal
  2. Is stronger
  3. Is gentle on instruments
  4. Removes lumens
Show answer
Answer: C. Is gentle on instruments
Protects instrument materials.

Report an error in this question

10. Rinsing after cleaning is done to:

  1. Dry items
  2. Add soil
  3. Remove detergent residue
  4. Label items
Show answer
Answer: C. Remove detergent residue
Residue may interfere with later steps.

Report an error in this question

Questions 11 to 20

11. Which water is recommended for the final rinse of instruments in US practice?

  1. Critical water (e.g., deionized, RO, distilled)
  2. Saline
  3. Untreated tap water
  4. Hot soapy water
Show answer
Answer: A. Critical water (e.g., deionized, RO, distilled)
US practice: treated water reduces spots, residues and corrosion.

Report an error in this question

12. An ultrasonic cleaner's performance is commonly checked with a:

  1. Sound test
  2. Color test
  3. Weight test
  4. Cavitation test (e.g., foil test)
Show answer
Answer: D. Cavitation test (e.g., foil test)
US practice: test regularly per manufacturer IFU.

Report an error in this question

13. Enzymatic detergents are used to break down:

  1. Organic soil such as protein and blood
  2. Plastic only
  3. Metal
  4. Glass
Show answer
Answer: A. Organic soil such as protein and blood
US practice: match detergent to the soil and IFU.

Report an error in this question

14. Lubricants used on instruments should be:

  1. Any oil
  2. Petroleum-based
  3. Silicone spray only
  4. Water-soluble and steam-permeable
Show answer
Answer: D. Water-soluble and steam-permeable
US practice: only approved instrument lubricants.

Report an error in this question

15. Washer-disinfector efficacy is verified through:

  1. Visual only once
  2. Never
  3. Routine cleaning-efficacy testing per policy
  4. Guessing
Show answer
Answer: C. Routine cleaning-efficacy testing per policy
US practice: routine tests and preventive maintenance.

Report an error in this question

16. Which brush is used to clean a narrow lumen?

  1. A wire brush that fits the sink drain
  2. A toothbrush used on the outer surface only
  3. A lumen brush matching the channel diameter
  4. A flat sponge soaked in detergent
Show answer
Answer: C. A lumen brush matching the channel diameter
Size matters for contact and safety.

Report an error in this question

17. Why should delicate microsurgical instruments be cleaned separately?

  1. To save water
  2. To prevent damage from heavier instruments
  3. To speed up drying
  4. To change their color
Show answer
Answer: B. To prevent damage from heavier instruments
Protect fine tips.

Report an error in this question

18. Which method reaches crevices and joints that brushes cannot?

  1. Labeling
  2. Air drying
  3. Wiping with a cloth
  4. Ultrasonic cleaning
Show answer
Answer: D. Ultrasonic cleaning
Cavitation works in small gaps.

Report an error in this question

19. How should instruments be arranged in a tray for washing?

  1. Heavy items at the bottom, delicate items on top
  2. Wrapped tightly
  3. Delicate at the bottom
  4. All piled in a heap
Show answer
Answer: A. Heavy items at the bottom, delicate items on top
Prevents damage.

Report an error in this question

20. Why avoid hot water for the first rinse of blood-soiled instruments?

  1. It cools the metal
  2. It is too cheap
  3. Heat can fix protein soil onto the surface
  4. It is too clean
Show answer
Answer: C. Heat can fix protein soil onto the surface
Use cool or lukewarm water first.

Report an error in this question

Questions 21 to 30

21. The manual cleaning sink should be filled with:

  1. Plain hot water only
  2. Detergent solution at the right dilution
  3. Salt water
  4. Bleach
Show answer
Answer: B. Detergent solution at the right dilution
Follow the label.

Report an error in this question

22. Brushes for instruments should be:

  1. Steel wool
  2. Hard stone
  3. Wire brushes
  4. Soft-bristled and non-metal
Show answer
Answer: D. Soft-bristled and non-metal
Avoids scratching.

Report an error in this question

23. Steel wool should not be used because it:

  1. Cleans perfectly
  2. Is too clean
  3. Is too soft
  4. Scratches the surface and invites corrosion
Show answer
Answer: D. Scratches the surface and invites corrosion
Scratches trap soil.

Report an error in this question

24. Lumens are flushed using:

  1. A syringe or pressure gun with detergent solution
  2. Compressed air only
  3. A coin
  4. A dry cloth
Show answer
Answer: A. A syringe or pressure gun with detergent solution
Flushing removes inner soil.

Report an error in this question

25. A pressure gun is useful for:

  1. Labeling
  2. Packing trays
  3. Cutting bone
  4. Flushing lumens and cannulated devices
Show answer
Answer: D. Flushing lumens and cannulated devices
Forces water through channels.

Report an error in this question

26. In an ultrasonic cleaner, instruments should be:

  1. Stacked high in a dry tank
  2. Half covered and packed tightly
  3. Fully covered by solution and not overloaded
  4. Placed in a bag on the tank bottom
Show answer
Answer: C. Fully covered by solution and not overloaded
Overloading blocks cavitation.

Report an error in this question

27. Instruments in an ultrasonic cleaner should be placed:

  1. On the bottom
  2. In a basket, not on the tank bottom
  3. In a bag
  4. Wrapped
Show answer
Answer: B. In a basket, not on the tank bottom
Prevents tank damage.

Report an error in this question

28. Ultrasonic cleaning time follows:

  1. The maker and detergent instructions
  2. A guess
  3. The weather
  4. Staff mood
Show answer
Answer: A. The maker and detergent instructions
Too long can harm some items.

Report an error in this question

29. Ultrasonic solution should be changed:

  1. Only if empty
  2. When visibly soiled or per policy
  3. Yearly
  4. Never
Show answer
Answer: B. When visibly soiled or per policy
Dirty solution cleans poorly.

Report an error in this question

30. Which items must stay out of ultrasonic cleaners?

  1. All trays
  2. All steel items
  3. Those the IFU prohibits, such as some optics
  4. All scissors
Show answer
Answer: C. Those the IFU prohibits, such as some optics
Always check the IFU.

Report an error in this question

Questions 31 to 40

31. After ultrasonic cleaning, instruments are:

  1. Rinsed thoroughly
  2. Left to soak
  3. Oiled
  4. Packed wet
Show answer
Answer: A. Rinsed thoroughly
Remove loosened soil.

Report an error in this question

32. In a washer-disinfector, hinged instruments are loaded:

  1. In a heap
  2. Open and secured
  3. Closed tightly
  4. Wrapped
Show answer
Answer: B. Open and secured
Spray must reach joints.

Report an error in this question

33. Cups and bowls in a washer are placed:

  1. Stacked
  2. Facing up
  3. Facing down so water drains
  4. Lidded
Show answer
Answer: C. Facing down so water drains
Prevents pooling.

Report an error in this question

34. Cannulated instruments in a washer are connected to:

  1. Nothing
  2. The door
  3. The flush ports or lumen adapters
  4. The drain only
Show answer
Answer: C. The flush ports or lumen adapters
Ensures internal cleaning.

Report an error in this question

35. A washer-disinfector cycle typically includes pre-wash, wash, rinse, disinfect and:

  1. Label
  2. Wrap
  3. Store
  4. Dry
Show answer
Answer: D. Dry
The usual sequence.

Report an error in this question

36. Washer chemical levels are checked:

  1. Never
  2. By smell
  3. Yearly
  4. Daily or per policy
Show answer
Answer: D. Daily or per policy
Empty tanks mean poor cleaning.

Report an error in this question

37. Washer printouts are reviewed:

  1. Never
  2. Before items are released
  3. Next month
  4. By visitors
Show answer
Answer: B. Before items are released
Check parameters.

Report an error in this question

38. A daily washer check includes spray arms, filters and:

  1. Chemical levels
  2. Labels
  3. Wall color
  4. Windows
Show answer
Answer: A. Chemical levels
Basic care.

Report an error in this question

39. A cart washer cleans:

  1. Gloves
  2. Linen
  3. Carts and containers
  4. Drapes
Show answer
Answer: C. Carts and containers
Keeps transport clean.

Report an error in this question

40. Water temperature for manual cleaning follows:

  1. Ice cold always
  2. The detergent label
  3. A guess
  4. Boiling always
Show answer
Answer: B. The detergent label
Hot water can fix protein.

Report an error in this question

Questions 41 to 50

41. Enzymatic soak solution is changed:

  1. After each use or when dirty
  2. Yearly
  3. Monthly
  4. Never
Show answer
Answer: A. After each use or when dirty
Old solution fails.

Report an error in this question

42. Sharp instruments are handled:

  1. In bare hands
  2. In bags
  3. Tossed in a heap
  4. Individually with the points down in a basket
Show answer
Answer: D. Individually with the points down in a basket
Prevents injuries.

Report an error in this question

43. Instruments should never be:

  1. Opened
  2. Rinsed
  3. Thrown or dropped into the sink
  4. Brushed
Show answer
Answer: C. Thrown or dropped into the sink
Rough handling damages them.

Report an error in this question

44. Delicate instruments are protected using:

  1. Paper bags
  2. Nothing
  3. Silicone mats or protective trays
  4. Cloth only
Show answer
Answer: C. Silicone mats or protective trays
Prevents tip damage.

Report an error in this question

45. Dried-on soil is first treated by:

  1. Soaking in enzymatic solution per label
  2. Dry brushing
  3. Painting
  4. Boiling
Show answer
Answer: A. Soaking in enzymatic solution per label
Softens soil.

Report an error in this question

46. Rust stains are removed with:

  1. Dry wiping with a paper towel
  2. An approved rust remover, then the cause is checked
  3. Steel wool and household bleach
  4. Hot saline soaking overnight
Show answer
Answer: B. An approved rust remover, then the cause is checked
Find why it rusted.

Report an error in this question

47. Detergent left on instruments can:

  1. Stain or irritate tissue
  2. Nothing
  3. Improve shine
  4. Prevent corrosion
Show answer
Answer: A. Stain or irritate tissue
Rinse thoroughly.

Report an error in this question

48. The final manual rinse uses:

  1. Saline
  2. Dirty water
  3. Treated water
  4. Any liquid
Show answer
Answer: C. Treated water
Prevents spots.

Report an error in this question

49. Instruments are dried with:

  1. Paper
  2. Nothing
  3. A clean lint-free cloth or filtered air
  4. A dirty towel
Show answer
Answer: C. A clean lint-free cloth or filtered air
Moisture promotes corrosion.

Report an error in this question

50. Compressed air for drying must be:

  1. Filtered and regulated
  2. Maximum pressure
  3. Oily
  4. Unfiltered
Show answer
Answer: A. Filtered and regulated
Dirty air recontaminates.

Report an error in this question

Questions 51 to 52

51. Cleaning chemicals should never be:

  1. Labeled
  2. Measured
  3. Mixed unless the label allows
  4. Stored properly
Show answer
Answer: C. Mixed unless the label allows
Dangerous reactions.

Report an error in this question

52. Cleaning solutions should be:

  1. Kept forever
  2. Unlabeled
  3. Shared
  4. Labeled and used before expiry
Show answer
Answer: D. Labeled and used before expiry
Safety rule.

Report an error in this question

Related chapters

Continue learning

CSSD interview questions Mock tests MCQ practice CSSD NABH checklist

Frequently asked questions

How many Instrument Cleaning & Decontamination Techniques MCQs are available?

This page has 52 free MCQs on Instrument Cleaning & Decontamination Techniques with answers and explanations. More are added over time.

Is Instrument Cleaning & Decontamination Techniques practice free?

Yes. You can practice without login or payment.

Are these official CSSD exam questions?

No. They are original practice questions written for learning.