Microbiological Quality – CSSD MCQ Questions and Study Notes
Water must also be controlled for bacteria, biofilm and endotoxin. Practice free CSSD MCQ questions on this topic below.
Take the Microbiological Quality practice test All 45 chapters
Learning objectives
- Understand the key points of this topic
- Apply them in daily reprocessing practice
Study notes
Bacteria stick to wet surfaces and form biofilm, especially in storage tanks and dead legs. Dead gram-negative bacteria release endotoxin. Regular sanitization, moving water and culture testing keep microbial quality in check.
Important points
- Biofilm forms in stagnant water
- Sanitize regularly
- Test with cultures
Key terms
Biofilm Endotoxin Dead leg
Practice MCQs on Microbiological Quality
Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.
Questions 1 to 10
1. Biofilm is:
- A protective coating on stainless steel
- A slimy layer of bacteria on wet surfaces
- A disinfectant film on pipes
- A dry crust of mineral scale
Show answer
It protects bacteria.
2. Which part of a water system is a biofilm risk?
- New filters only
- Dry pipes
- Storage tanks and dead legs
- Labels
Show answer
Stagnant water is the problem.
3. Endotoxin comes from:
- Steam
- Resin
- Sand
- Dead gram-negative bacteria
Show answer
Sterilization does not remove it.
4. Final rinse water should have:
- Unknown counts
- Any count
- Low microbial counts within limits
- High counts
Show answer
Limits protect patients.
5. What helps control bacteria in water systems?
- Adding detergent to the storage tank
- Retesting once a year only
- Regular sanitization and avoiding stagnant water
- Leaving water standing in unused pipes
Show answer
Keep water moving.
6. Microbial water quality is checked by:
- Culture tests with colony counts
- A thermometer
- A TDS meter
- A scale
Show answer
Meters do not detect bacteria.
7. Bacteria counts in water are usually reported as:
- Meters
- kg per tank
- CFU per mL or per 100 mL
- Volts
Show answer
Colony counts.
8. CFU stands for:
- Clean filter use
- Colony-forming units
- Cold flow units
- Central fluid unit
Show answer
Counts viable bacteria.
9. Water for culture is collected in:
- A coffee cup
- A plastic bag
- Any jar
- A sterile bottle
Show answer
Avoids contamination.
10. Sodium thiosulfate in a sample bottle neutralizes:
- Hardness
- Silica
- Chloride
- Chlorine
Show answer
So bacteria are not killed.
Questions 11 to 20
11. Water samples for culture should be:
- Left for a week
- Delivered to the lab promptly and kept cool
- Frozen solid
- Kept warm
Show answer
Bacteria multiply with time.
12. Hot-water sanitization can control bacteria:
- If the system is designed for it
- Never
- In any plastic pipe
- Only in winter
Show answer
Follow the system maker.
13. Chemical sanitization of a water system uses:
- Approved agents followed by rinsing
- Salt only
- Household bleach at random
- Soap only
Show answer
Follow the maker.
14. UV light in a water loop:
- Removes endotoxin
- Removes silica
- Softens water
- Reduces bacteria but does not clean pipes
Show answer
Not a substitute for sanitization.
15. A 0.2 micron filter is used to:
- Add chlorine
- Remove bacteria from water
- Remove silica
- Soften water
Show answer
A sterilizing-grade filter.
16. Water filters are replaced:
- Only when the water stops flowing completely
- Every day regardless of the plan
- Never, because they last for ever
- On schedule or when performance shows the need
Show answer
Old filters grow bacteria.
17. Dead legs are dangerous because:
- Water stagnates in them
- They are cold
- They are shiny
- They are long
Show answer
Stagnation grows biofilm.
18. Rising bacterial counts should lead to:
- Sanitizing and investigating the cause
- More detergent
- Ignoring them
- Hiding them
Show answer
Act on trends.
19. A common water bacterium is:
- Chloride
- Penicillin
- Silica
- Pseudomonas
Show answer
Gram-negative and slime-forming.
20. Endotoxin in water is measured by the:
- LAL test
- Color test
- Weight test
- Litmus test
Show answer
Limulus amebocyte lysate.
Related chapters
- Previous: Conductivity
- Next: Water Used in Washers
- Chapter 38: Silica
- Chapter 39: Conductivity
- Chapter 41: Water Used in Washers
- Chapter 42: Water Used for Sterilization
Continue learning
CSSD interview questions Mock tests MCQ practice CSSD NABH checklist
Frequently asked questions
How many Microbiological Quality MCQs are available?
This page has 20 free MCQs on Microbiological Quality with answers and explanations. More are added over time.
Is Microbiological Quality practice free?
Yes. You can practice without login or payment.
Are these official CSSD exam questions?
No. They are original practice questions written for learning.