Sterilization Principles – CSSD MCQ Questions and Study Notes

Sterilization principles explain how all viable microorganisms are destroyed. Practice free CSSD MCQ questions on this topic below.

Take the Sterilization Principles practice test All 45 chapters

Learning objectives

Study notes

Sterilization is a process that eliminates all forms of microbial life, including spores. Cleaning must come first because soil protects microorganisms.

Effectiveness depends on cleaning, exposure time, temperature or concentration, and contact with all surfaces. Spaulding classification guides the level of processing: critical items need sterilization, semi-critical need at least high-level disinfection, non-critical need low-level disinfection.

Important points

Key terms

Spaulding classification Sterility Assurance Level Spore Bioburden

Practice MCQs on Sterilization Principles

Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.

Questions 1 to 10

1. Sterilization destroys:

  1. Only viruses
  2. All microorganisms including spores
  3. Only fungi
  4. Only bacteria
Show answer
Answer: B. All microorganisms including spores
Including spores.

Report an error in this question

2. Critical items contact:

  1. Sterile tissue or blood
  2. Bedrails
  3. Floors
  4. Intact skin
Show answer
Answer: A. Sterile tissue or blood
Highest risk.

Report an error in this question

3. Critical items require:

  1. Sterilization
  2. Rinsing
  3. Nothing
  4. Wiping
Show answer
Answer: A. Sterilization
Sterile use.

Report an error in this question

4. Semi-critical items need at least:

  1. High-level disinfection
  2. No processing
  3. Dusting
  4. Wipe
Show answer
Answer: A. High-level disinfection
Mucous membranes.

Report an error in this question

5. The most resistant organisms are:

  1. Vegetative bacteria
  2. Enveloped viruses
  3. Bacterial spores
  4. Yeasts
Show answer
Answer: C. Bacterial spores
Spores resist most.

Report an error in this question

6. Cleaning precedes sterilization because:

  1. It shortens cycles
  2. It saves cost
  3. It is optional
  4. Soil protects microbes
Show answer
Answer: D. Soil protects microbes
Residue blocks sterilant.

Report an error in this question

7. Sterility Assurance Level is typically:

  1. 10^-6
  2. 1
  3. 10^-1
  4. 10^-2
Show answer
Answer: A. 10^-6
One in a million.

Report an error in this question

8. Non-critical items touch:

  1. Sterile tissue
  2. Blood
  3. Bone
  4. Intact skin
Show answer
Answer: D. Intact skin
Low risk.

Report an error in this question

9. Sterilant must contact:

  1. Only handles
  2. Nothing
  3. All surfaces
  4. Only outer surfaces
Show answer
Answer: C. All surfaces
Penetration is essential.

Report an error in this question

10. Which affects sterilization success?

  1. Room paint
  2. Time, temperature, contact
  3. Packaging color
  4. Music
Show answer
Answer: B. Time, temperature, contact
Key parameters.

Report an error in this question

Questions 11 to 20

11. Which is generally regarded as the most resistant to disinfection and sterilization?

  1. Prions
  2. Vegetative bacteria
  3. Fungi
  4. Lipid viruses
Show answer
Answer: A. Prions
US practice: prions are more resistant than spores.

Report an error in this question

12. Flexible endoscopes are classified as:

  1. Critical
  2. Semi-critical
  3. Non-critical
  4. Sterile only
Show answer
Answer: B. Semi-critical
US practice: Spaulding classification.

Report an error in this question

13. A Sterility Assurance Level of 10^-6 means:

  1. Six microorganisms remain per item
  2. All microorganisms are killed in six minutes
  3. One in ten probability of a viable microorganism
  4. One in a million probability of a viable microorganism
Show answer
Answer: D. One in a million probability of a viable microorganism
US practice: standard for sterile devices.

Report an error in this question

14. Arthroscopes and laparoscopes are classified as:

  1. Non-critical
  2. Semi-critical
  3. Environmental
  4. Critical
Show answer
Answer: D. Critical
US practice: enter sterile tissue.

Report an error in this question

15. Under Spaulding classification, bed rails are:

  1. Semi-critical
  2. Critical
  3. Non-critical
  4. Sterile
Show answer
Answer: C. Non-critical
US practice: contact intact skin only.

Report an error in this question

16. Hot air oven sterilization is commonly done at:

  1. 80 °C for 5 minutes
  2. 121 °C for 60 minutes
  3. 100 °C for 10 minutes
  4. 160 °C for 60 minutes
Show answer
Answer: D. 160 °C for 60 minutes
India practice: used for glassware, powders, oils.

Report an error in this question

17. Boiling water at 100 °C:

  1. Does not kill bacterial spores
  2. Is a sterilizer
  3. Sterilizes fully
  4. Kills prions
Show answer
Answer: A. Does not kill bacterial spores
India practice: it is disinfection only.

Report an error in this question

18. Which method is suitable for oils and powders?

  1. Boiling
  2. Chemical wipe
  3. Autoclave
  4. Hot air oven
Show answer
Answer: D. Hot air oven
India practice: dry heat penetrates without moisture.

Report an error in this question

19. Gamma radiation is commonly used to sterilize:

  1. Instruments in OT
  2. Linen
  3. Disposable syringes and gloves
  4. Metal trays
Show answer
Answer: C. Disposable syringes and gloves
India practice: cold sterilization in industry.

Report an error in this question

20. 2% glutaraldehyde for high-level disinfection is typically used for:

  1. 5 seconds
  2. 1 minute
  3. Not used
  4. About 20 minutes
Show answer
Answer: D. About 20 minutes
India practice: follow manufacturer IFU; longer time for sterilization.

Report an error in this question

Questions 21 to 30

21. Disinfection does not necessarily kill:

  1. Bacterial spores
  2. Vegetative bacteria
  3. Some viruses
  4. Yeast
Show answer
Answer: A. Bacterial spores
Only sterilization does.

Report an error in this question

22. An antiseptic is used on:

  1. Floors
  2. Instruments
  3. Linen
  4. Living tissue
Show answer
Answer: D. Living tissue
Skin antisepsis.

Report an error in this question

23. A disinfectant is used on:

  1. Eyes
  2. Inanimate objects and surfaces
  3. Wounds
  4. Skin
Show answer
Answer: B. Inanimate objects and surfaces
Not for tissue.

Report an error in this question

24. Low-level disinfection kills:

  1. Only viruses, never bacteria
  2. All bacterial spores and prions
  3. Nothing, it only cleans
  4. Most vegetative bacteria and some viruses
Show answer
Answer: D. Most vegetative bacteria and some viruses
Used for non-critical items.

Report an error in this question

25. Intermediate-level disinfection kills:

  1. Only spores
  2. Mycobacteria and most viruses and fungi
  3. Nothing
  4. Only dust
Show answer
Answer: B. Mycobacteria and most viruses and fungi
Above low-level.

Report an error in this question

26. The D-value is the time to reduce a microbial population by:

  1. 90 percent (one log)
  2. 50 percent
  3. 1 percent
  4. 10 percent
Show answer
Answer: A. 90 percent (one log)
Used to compare resistance.

Report an error in this question

27. Each log reduction is a:

  1. One percent decrease
  2. Two-fold decrease
  3. Five percent decrease
  4. Ten-fold decrease
Show answer
Answer: D. Ten-fold decrease
10 to 1 reduction.

Report an error in this question

28. Moist heat compared with dry heat:

  1. Is slower
  2. Needs higher temperature
  3. Is weaker
  4. Kills at lower temperature and shorter time
Show answer
Answer: D. Kills at lower temperature and shorter time
Steam transfers heat quickly.

Report an error in this question

29. Dry heat kills microbes mainly by:

  1. Oxidation
  2. Filtering
  3. Dissolving
  4. Freezing
Show answer
Answer: A. Oxidation
Needs high heat and time.

Report an error in this question

30. Sterilizing filtration is used for:

  1. Metal instruments
  2. Linen
  3. Heat-sensitive liquids and air
  4. Wraps
Show answer
Answer: C. Heat-sensitive liquids and air
Removes microbes physically.

Report an error in this question

Questions 31 to 40

31. Electron-beam sterilization is used industrially for:

  1. Linen
  2. Single-use medical products
  3. Hospital floors
  4. Water tanks
Show answer
Answer: B. Single-use medical products
A radiation method.

Report an error in this question

32. Pasteurization is:

  1. Packaging
  2. Sterilization
  3. Cleaning
  4. Not sterilization
Show answer
Answer: D. Not sterilization
Reduces some microbes only.

Report an error in this question

33. Sterile means:

  1. Dry
  2. Disinfected
  3. Free of all viable microorganisms
  4. Clean-looking
Show answer
Answer: C. Free of all viable microorganisms
The strict definition.

Report an error in this question

34. The aim of aseptic technique is to:

  1. Add microbes
  2. Speed work
  3. Maintain sterility
  4. Clean floors
Show answer
Answer: C. Maintain sterility
Protects patients.

Report an error in this question

35. Process validation commonly includes:

  1. Counting trays and labels each shift
  2. Colour, weight and pack size checks
  3. Installation, operational and performance qualification
  4. Staff satisfaction surveys and menu reviews
Show answer
Answer: C. Installation, operational and performance qualification
Proves the process works.

Report an error in this question

36. Inadequate cleaning raises the:

  1. Bioburden challenge
  2. Weight
  3. Shine
  4. Speed
Show answer
Answer: A. Bioburden challenge
More microbes to kill.

Report an error in this question

37. Lumened devices are harder to sterilize because:

  1. The sterilant must reach the inside
  2. They are cheap
  3. They are light
  4. They are short
Show answer
Answer: A. The sterilant must reach the inside
Penetration challenge.

Report an error in this question

38. Heat-sensitive items need:

  1. No processing
  2. Dry heat
  3. Low-temperature sterilization
  4. Longer boiling
Show answer
Answer: C. Low-temperature sterilization
Check the IFU.

Report an error in this question

39. Packaging must allow:

  1. Noise
  2. Light
  3. Water pooling
  4. Sterilant penetration
Show answer
Answer: D. Sterilant penetration
And maintain sterility after.

Report an error in this question

40. A compromised package means the item is:

  1. Not sterile
  2. Better sterile
  3. Still sterile
  4. Dry only
Show answer
Answer: A. Not sterile
Reprocess it.

Report an error in this question

Questions 41 to 50

41. Implants are:

  1. Semi-critical
  2. Critical items
  3. Environmental
  4. Non-critical
Show answer
Answer: B. Critical items
Contact sterile tissue.

Report an error in this question

42. Respiratory equipment contacting mucous membranes is:

  1. Semi-critical
  2. Environmental
  3. Critical
  4. Non-critical
Show answer
Answer: A. Semi-critical
Needs at least HLD.

Report an error in this question

43. A stethoscope touching intact skin is:

  1. Non-critical
  2. Critical
  3. Sterile
  4. Semi-critical
Show answer
Answer: A. Non-critical
Low-level disinfection.

Report an error in this question

44. Cleaning reduces bioburden by:

  1. Removing most organisms and soil
  2. Adding detergent only
  3. Heating only
  4. Drying
Show answer
Answer: A. Removing most organisms and soil
First step.

Report an error in this question

45. Biofilm is difficult because it:

  1. Resists disinfectants
  2. Dissolves in water
  3. Is sterile
  4. Is clear
Show answer
Answer: A. Resists disinfectants
Remove by cleaning.

Report an error in this question

46. Material compatibility must be considered because:

  1. It looks good
  2. All materials are identical
  3. It saves time
  4. Some methods damage some materials
Show answer
Answer: D. Some methods damage some materials
Check the IFU.

Report an error in this question

47. The cycle chosen should match:

  1. The room
  2. Staff mood
  3. The color
  4. The load type and device IFU
Show answer
Answer: D. The load type and device IFU
Use validated cycles.

Report an error in this question

48. Sterilization records are:

  1. Kept for traceability
  2. Optional
  3. Hidden
  4. Discarded
Show answer
Answer: A. Kept for traceability
Needed for audits.

Report an error in this question

49. The sterilization level needed depends on:

  1. The risk of the device
  2. Device color
  3. Brand only
  4. Staff lunch
Show answer
Answer: A. The risk of the device
Spaulding logic.

Report an error in this question

50. A heat-resistant spore is used as a test organism because:

  1. It is cheap
  2. If it dies, less resistant organisms die
  3. It is rare
  4. It is blue
Show answer
Answer: B. If it dies, less resistant organisms die
A worst-case challenge.

Report an error in this question

Questions 51 to 52

51. Sterilant contact time is:

  1. The time between two cycles
  2. The exposure needed for the process to work
  3. The time spent packing the load
  4. The time the load takes to dry
Show answer
Answer: B. The exposure needed for the process to work
Follow the validated time.

Report an error in this question

52. Sterility is maintained by:

  1. The sterile barrier and correct handling
  2. Heat in storage
  3. Dust
  4. Wishing
Show answer
Answer: A. The sterile barrier and correct handling
Until the package is opened.

Report an error in this question

Related chapters

Continue learning

CSSD interview questions Mock tests MCQ practice CSSD NABH checklist

Frequently asked questions

How many Sterilization Principles MCQs are available?

This page has 52 free MCQs on Sterilization Principles with answers and explanations. More are added over time.

Is Sterilization Principles practice free?

Yes. You can practice without login or payment.

Are these official CSSD exam questions?

No. They are original practice questions written for learning.